Failure Analysis of Galvanized Iron Pipe at Perumda Tirta Kanjuruhan

Cynthia Rosa Pramita, Agus Suprapto, Ike Widyastuti

Abstract


The most commonly used type of water pipe is iron pipe or commonly called Galvanized Iron pipe. The disadvantage of GI pipe is that it rusts easily. So it can result in degradation, decreased efficiency and construction, poor water quality, and higher maintenance costs. Water channeled through rusty pipes will pollute the water and adversely affect the health of those who consume it. This study aims to determine the factors causing failures of GI pipe in the distribution pipeline that have failed due to corrosion. The tested pipes is 1/2"ᴓ sized, 5-year-old corroded pipe whose distribution uses a gravity system and a pumping system. To support this analysis, operational data on fluid and environmental conditions around the pipeline are needed, observations on macro and micro structures, and hardness testing. The corrosion rate is calculated through the thickness loss method and the corrosion rate in the gravity system is 0.153 mm / year that higher than pipe in pumping system. Microstructure observations support the characterization of the material that this pipe is a mild steel, where this type of steel has a high Fe content so it is vulnerable to corrosion attacks. Rockwell hardness testing showed that the corrosion rate is directly proportional to the hardness value of the pipeline. The results of the analysis show that the environment around the pipe which has low soil resistivity and high humidity levels is the main factor in the occurrence of uniform corrosion of the pipe. The selection of inappropriate materials is also supportive as the cause of corrosion occurring.

Keywords


failure analysis; corrosion; galavanized iron; rockwell hardness; microstructure

Full Text:

PDF

References


A. Royani, S. Prifiharni, G. Priyotomo, J. Triwardono, and S. Sundjono, “Performa Korosi Baja Karbon pada Uji Simulasi Pipa untuk Sistem Saluran Air Pendingin,” Metalurgi, vol. 34, no. 2, pp. 49–60, 2019.

A. Rustandi, M. Adyutatama, E. Fadly, and N. Subekti, “Corrosion Rate of Carbon Steel for Flowline and Pipeline as Transmission Pipe in Natural Gas Production With Co2 Content,” MAKARA Technol. Ser., vol. 16, no. 1, 2012, doi: 10.7454/mst.v16i1.1056.

M. Fonte, L. Reis, V. Infante, and M. Freitas, “Failure analysis of cylinder head studs of a four stroke marine diesel engine,” Eng. Fail. Anal., vol. 101, no. March, pp. 298–308, 2019, doi: 10.1016/j.engfailanal.2019.03.026.

Y. K. Afandi, I. S. Arief, and A. Amiadji, “Analisa Laju Korosi pada Pelat Baja Karbon dengan Variasi Ketebalan Coating,” J. Tek. ITS, vol. 4, no. 1, pp. 1–5, 2015.

A. Bensely, D. Senthilkumar, D. Mohan Lal, G. Nagarajan, and A. Rajadurai, “Effect of cryogenic treatment on tensile behavior of case carburized steel-815M17,” Mater. Charact., vol. 58, no. 5, pp. 485–491, 2007, doi: 10.1016/j.matchar.2006.06.019.

V. 4 ASM International Handbook, “ASM Handbook: Heat Treating,” Technology, vol. 4, p. 3470, 2001, doi: 10.1016/S0026-0576(03)90166-8.

A. Suprapto, A. Iswantoko, and I. Widyastuti, “Impact of cryogenic treatment and temper to carbide toollife on turning process for Al T-6061,” Int. J. Appl. Eng. Res., vol. 9, no. 24, pp. 30643–30650, 2014.

R. Singh, D. Sachan, R. Verma, S. Goel, R. Jayaganthan, and A. Kumar, “Mechanical behavior of 304 Austenitic stainless steel processed by cryogenic rolling,” Mater. Today Proc., vol. 5, no. 9, pp. 16880–16886, 2018, doi: 10.1016/j.matpr.2018.04.090.




DOI: https://doi.org/10.26905/jtmt.v19i2.12015

Refbacks

  • There are currently no refbacks.